THREE-DIMENSIONAL ASSESSMENT OF THERMAL-HYDRAULIC BEHAVIOUR IN HEAT EXCHANGERS FITTED BY WAVY ANNULAR FINS
dc.authorid | MENNI, Younes/0000-0003-1475-3743 | |
dc.contributor.author | Djeffal, Fares | |
dc.contributor.author | Tahrour, Farouk | |
dc.contributor.author | Bordja, Lyes | |
dc.contributor.author | Akgul, Ali | |
dc.contributor.author | Jarrar, Rabab | |
dc.contributor.author | Asad, Jihad | |
dc.contributor.author | Menni, Younes | |
dc.date.accessioned | 2024-12-24T19:30:44Z | |
dc.date.available | 2024-12-24T19:30:44Z | |
dc.date.issued | 2022 | |
dc.department | Siirt Üniversitesi | |
dc.description.abstract | In this study, numerical studies to clarify the influence of wave number and amplitude on thermal-flow behavior of wavy annular finned-and-tube heat exchangers are described. For a range of Reynolds number from 4400 to 14300, the influence of wave amplitude, 1.5 <= A <= 4.5 mm, and wave numbers, 2 <= N-w <= 6, on forced convection heat transfer was examined. It was revealed that the wave amplitude and number have an impact on the heat flux, Colburn factor, and friction factor. The wavy annular-fins with a 3 mm amplitude and N-w = 4 waves obtained the highest values at all Reynolds numbers in terms of the overall performance criterion (j/f(1/3)). | |
dc.description.sponsorship | Palestine Technical University-Kadoorie | |
dc.description.sponsorship | The authors R. Jarrar and Jihad Asad would like to thank Palestine Technical University-Kadoorie for supporting this work financially. | |
dc.identifier.doi | 10.2298/TSCI22S1485D | |
dc.identifier.endpage | 493 | |
dc.identifier.issn | 0354-9836 | |
dc.identifier.issn | 2334-7163 | |
dc.identifier.scopus | 2-s2.0-85146987518 | |
dc.identifier.scopusquality | Q3 | |
dc.identifier.startpage | 485 | |
dc.identifier.uri | https://doi.org/10.2298/TSCI22S1485D | |
dc.identifier.uri | https://hdl.handle.net/20.500.12604/7645 | |
dc.identifier.volume | 26 | |
dc.identifier.wos | WOS:000916468800046 | |
dc.identifier.wosquality | Q4 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.language.iso | en | |
dc.publisher | Vinca Inst Nuclear Sci | |
dc.relation.ispartof | Thermal Science | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.snmz | KA_20241222 | |
dc.subject | heat exchanger | |
dc.subject | fin | |
dc.subject | Colburn factor | |
dc.subject | heat transfer | |
dc.subject | assessment | |
dc.title | THREE-DIMENSIONAL ASSESSMENT OF THERMAL-HYDRAULIC BEHAVIOUR IN HEAT EXCHANGERS FITTED BY WAVY ANNULAR FINS | |
dc.type | Article |