Pleurotus eryngii immobilized amberlite XAD-16 as a solid-phase biosorbent for preconcentrations of Cd2+ and Co2+ and their determination by ICP-OES
dc.authorid | https://orcid.org/0000-0002-5505-2700 | en_US |
dc.contributor.author | Özdemir, Sadin | |
dc.contributor.author | Okumuş, Veysi | |
dc.contributor.author | Kılınç, Ersin | |
dc.contributor.author | Bilgetekin, Havin | |
dc.contributor.author | Dündar, Abdurrahman | |
dc.contributor.author | Ziyadanoğulları, Berrin | |
dc.date.accessioned | 2019-12-26T05:39:45Z | |
dc.date.available | 2019-12-26T05:39:45Z | |
dc.date.issued | 2012 | en_US |
dc.department | Fen - Edebiyat Fakültesi | en_US |
dc.description.abstract | This article reports a method that is used for the preconcentration and determination of Cd and Co in vegetables, using Pleurotus eryngii immobilized Amberlite XAD-16 as a solid-phase biosorbent. The concentrations of metals were determined by inductively coupled plasma-optical spectrometry (ICP-OES). Critical parameters, such as the pH of the solution, flow rate, the amount of biosorbent, type and volume of eluent, and the sample volume, that affect the solid-phase extraction (SPE) procedure were optimized. The optimum extraction conditions were determined as being a pH of 6.0 for Cd and of 5.0 for Co; a sample flow rate of 2.0 mL min_1; 200.0 mg of biosorbent; and 5.0 mL of 1.0 mol L_1 HCl as eluent. The capacities of the biosorbent for metal uptake were found to be 11.3 and 9.8 mg g_1 for Cd and Co ions, respectively. Limit of quantitations (LOQs) were found to be 0.67 and 0.82 ng mL_1, respectively, for Cd and Co. The linear working curves were observed to be in the linear range from 1.0 to 50.0 ng mL_1, and possessed high correlation coefficients. The use of the SPE method showed 50.7- and 35.7-fold improvements in the sensitivities of ICP-OES. The developed method was successfully applied to NCS ZC-73014 (a certified reference tea sample). Relative standard deviations (RSD) were lower than 5.0%. The Cdand Co concentrations in the different parts (leave, root, stem, and fruit) of purslane, onion, rocket, okra, and aubergine were determined after microwave digestion and solid-phase extraction by P. eryngii immobilized on Amberlite XAD-16. | en_US |
dc.description.provenance | Submitted by Veysi OKUMUŞ (veysiokumus@siirt.edu.tr) on 2019-12-23T18:47:29Z No. of bitstreams: 1 A7.pdf: 279859 bytes, checksum: d2d234c48ca1b27c50b9b3a628610815 (MD5) | en |
dc.description.provenance | Approved for entry into archive by Esra Diriarın (esradiriarin@siirt.edu.tr) on 2019-12-26T05:39:45Z (GMT) No. of bitstreams: 1 A7.pdf: 279859 bytes, checksum: d2d234c48ca1b27c50b9b3a628610815 (MD5) | en |
dc.description.provenance | Made available in DSpace on 2019-12-26T05:39:45Z (GMT). No. of bitstreams: 1 A7.pdf: 279859 bytes, checksum: d2d234c48ca1b27c50b9b3a628610815 (MD5) Previous issue date: 2012 | en |
dc.identifier.citation | Okumuş, Veysi.(2012). Pleurotus eryngii immobilized amberlite XAD-16 as a solid-phase biosorbent for preconcentrations of Cd2+ and Co2+ and their determination by ICP-OES, Talanta, 99 (502-506). | en_US |
dc.identifier.endpage | 506 | en_US |
dc.identifier.pmid | 22967585 | |
dc.identifier.startpage | 502 | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.12604/2440 | |
dc.identifier.volume | 99 | en_US |
dc.identifier.wos | WOS:000309785300072 | |
dc.identifier.wosquality | Q1 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | PubMed | |
dc.institutionauthor | Okumuş, Veysi | |
dc.language.iso | en | en_US |
dc.publisher | Talanta | en_US |
dc.relation.ispartof | Talanta | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.snmz | KG_20241224 | |
dc.subject | Pleurotus eryngii | en_US |
dc.subject | Solid-phase extraction | en_US |
dc.subject | Cd2þ | en_US |
dc.subject | Co2þ | en_US |
dc.subject | ICP-OES | en_US |
dc.subject | Sensitivity improvement | en_US |
dc.title | Pleurotus eryngii immobilized amberlite XAD-16 as a solid-phase biosorbent for preconcentrations of Cd2+ and Co2+ and their determination by ICP-OES | en_US |
dc.type | Article | en_US |