Case studies on local mixed convection heat transfer coefficients along a radiant heated wall subjected to displacement ventilation
dc.authorid | Acikgoz, Ozgen/0000-0002-0095-829X | |
dc.authorid | Dalkilic, Ahmet Selim/0000-0002-5743-3937 | |
dc.authorid | Camci, Muhammet/0000-0003-4283-1307 | |
dc.authorid | Karakoyun, Yakup/0000-0003-1868-452X | |
dc.contributor.author | Camci, Muhammet | |
dc.contributor.author | Karakoyun, Yakup | |
dc.contributor.author | Acikgoz, Ozgen | |
dc.contributor.author | Dalkilic, Ahmet Selim | |
dc.date.accessioned | 2024-12-24T19:24:41Z | |
dc.date.available | 2024-12-24T19:24:41Z | |
dc.date.issued | 2023 | |
dc.department | Siirt Üniversitesi | |
dc.description.abstract | As the demand for energy-efficient air conditioning systems enabling thermal comfort criteria increases, the research into innovative systems that combine displacement ventilation and radiant heating is being more up-to-date. This work discusses local mixed convection heat transfer coefficients over a radiant heated wall in an experimental room coupled with displacement ventilation provided by a floor level nozzle. In the experimental chamber, the air enters the room either from the floor level of the analyzed heated wall as in scenario 1 or the opposite wall in scenario 2 in the upward direction. The intervals of air inlet temperature and velocity are set between 13-27 & DEG;C and 0-2.5 ms(-1), respectively. The obtained data have been analyzed from a physical point of view, and four correlations having R-sq. numbers of 0.93, 0.94, 0.94, and 0.98 have been developed for the local mixed convective heat transfer coefficients along a heated wall. The alterations of local convection heat transfer coefficients along an examined radiant heated wall affected by a slot diffuser delivering a lowest air inlet velocity of 0.5 ms(-1) and highest air inlet velocity of 2.5 ms(-1) are gained in the intervals of 2-5.8 Wm(-2) K-1 and 2.5-10 W m(-2) K-1, in turn. | |
dc.description.sponsorship | YTU Scientific Research Projects Coordination Department [FCD-2022-5092] | |
dc.description.sponsorship | AcknowledgementsThis study has been financially supported by YTU Scientific Research Projects Coordination Department, Project ID: FCD-2022-5092. | |
dc.identifier.doi | 10.1007/s10973-023-12262-6 | |
dc.identifier.endpage | 7854 | |
dc.identifier.issn | 1388-6150 | |
dc.identifier.issn | 1588-2926 | |
dc.identifier.issue | 15 | |
dc.identifier.scopus | 2-s2.0-85159718886 | |
dc.identifier.scopusquality | Q1 | |
dc.identifier.startpage | 7845 | |
dc.identifier.uri | https://doi.org/10.1007/s10973-023-12262-6 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12604/6098 | |
dc.identifier.volume | 148 | |
dc.identifier.wos | WOS:001023269000022 | |
dc.identifier.wosquality | Q2 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.language.iso | en | |
dc.publisher | Springer | |
dc.relation.ispartof | Journal of Thermal Analysis and Calorimetry | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
dc.rights | info:eu-repo/semantics/closedAccess | |
dc.snmz | KA_20241222 | |
dc.subject | Local convective heat transfer coefficient | |
dc.subject | Mixed convection | |
dc.subject | Radiant heated wall | |
dc.subject | Displacement ventilation | |
dc.subject | Temperature gradient | |
dc.title | Case studies on local mixed convection heat transfer coefficients along a radiant heated wall subjected to displacement ventilation | |
dc.type | Article |