Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Ersoz, Gulfem" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • [ X ]
    Öğe
    MULTI-INSTRUMENT ASSESSMENT OF PHYSICAL ACTIVITY IN FEMALE OFFICE WORKERS
    (Nofer Inst Occupational Medicine, Poland, 2016) Can, Sema; Gunduz, Nevin; Arslan, Ersan; Biernat, Elzbieta; Ersoz, Gulfem; Kilit, Bulent
    Objectives: The aim of this study was to examine the multi-instrument assessment of physical activity in female office workers. Material and Methods: Fifty healthy women (age (mean +/- standard deviation): 34.8 +/- 5.9 years, body height: 158 +/- 0.4 cm, body weight: 61.8 +/- 7.5 kg, body mass index: 24.6 +/- 2.7 kg/m(2)) workers from the same workplace volunteered to participate in the study. Physical activity was measured with the 7-day Physical Activity Assessment Questionnaire (7-d PAAQ), an objective multi-sensor armband tool, and also a waist-mounted pedometer, which were both worn for 7 days. Results: A significant correlation between step numbers measured by armband and pedometer was observed (r = 0.735), but the step numbers measured by these 2 methods were significantly different (10 941 +/- 2236 steps/day and 9170 +/- 2377 steps/day, respectively; p < 0.001). There was a weak correlation between the value of 7-d PAAQ total energy expenditure and the value of armband total energy expenditure (r = 0.394, p = 0.005). However, total energy expenditure values measured by armband and 7-d PAAQ were not significantly different (2081 +/- 370 kcal/day and 2084 +/- 197 kcal/day, respectively; p = 0.96). In addition, physical activity levels (average daily metabolic equivalents (MET)) measured by armband and 7-d PAAQ were not significantly different (1.45 +/- 0.12 MET/day and 1.47 +/- 0.24 MET/day, respectively; p = 0.44). Conclusions: The results of this study showed that the correlation between pedometer and armband measurements was higher than that between armband measurements and 7-d PAAQ self-reports. Our results suggest that none of the assessment methods examined here, 7-d PAAQ, pedometer, or armband, is sufficient when used as a single tool for physical activity level determination. Therefore, multi-instrument assessment methods are preferable.

| Siirt Üniversitesi | Kütüphane | Açık Bilim Politikası | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Siirt Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Siirt, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim